High-Density Rack Cooling Solution

Vertiv Liebert DCD

Manage heat at the rack level with a rear-door heat exchanger architecture designed to support room-neutral conditions in the data hall.

Heat Removal at the Source

Targeted, Space-Efficient Rack Cooling with Liebert DCD

Thermal loads generated by high-density racks cannot always be managed efficiently through room-level cooling alone.

Liebert DCD captures heat at the rack exhaust, helping reduce hot spots and returning air to the data hall at near-room temperature. This room-neutral approach supports a more controlled thermal architecture in IT environments with high-density compute, AI and GPU workloads.

Vertiv Liebert DCD rear door heat exchanger yüksek yoğunluklu rack soğutma çözümü

Up to 50 kW of Cooling per Rack

Designed for high-density applications from 5 to 50 kW, Liebert DCD supports different rack widths and capacity requirements through the DCD35, DCD47 and DCD50 models.

Vertiv Liebert DCD yüksek yoğunluklu veri merkezi için rack arka kapı soğutma modülü

Space-Efficient Installation

Mounts directly to the rear of the rack, helping preserve floor space for additional critical IT equipment.

Low Energy Consumption

Passive models require no fans, while active configurations use high-efficiency EC fans to help reduce operating costs.

Intelligent Monitoring and Scalability

Supports 0–100% capacity modulation and optional monitoring and control features for a more flexible response to changing heat loads.

Ideal Applications

High-Density and Expandable IT Environments

Liebert DCD is well suited to applications where rack-level heat density is increasing and room-level cooling alone is no longer sufficient. It is particularly relevant for high-density compute environments, colocation facilities, capacity-expansion projects in existing data centers and installations where space efficiency is critical.

Its rear-door design makes it easier to add targeted cooling without completely redesigning the existing data hall.

Recommended Applications

  • Data centers
  • Colocation and hosting environments
  • Educational institutions
  • Government facilities
  • Healthcare systems
  • Retail and distributed IT environments

Why Choose Liebert DCD?

Controlled, Room-Neutral Cooling for Critical IT

Liebert DCD manages heat at the rack level, helping reduce hot spots and maintain a more balanced thermal environment across the data hall. Instead of increasing cooling across the entire room, it enables a more targeted cooling strategy at the point of demand.

  • Space-saving rear-rack installation
  • 0–100% capacity modulation for variable load profiles
  • Passive or active cooling configurations

System Compatibility and Operational Flexibility

Its scalable, modular architecture allows additional rack-level cooling capacity to be deployed as IT loads grow.

  • Integration with existing chilled-water or compatible CDU systems
  • Multiple chilled-water connection options
  • Low-maintenance design with fewer moving components

Technical Highlights

Heat Removal at the Source

Captures heat at the rack exhaust, helping reduce the thermal load released into the data hall.

Passive or Active Configuration

Available as a passive rear door or an active module with EC fans for different rack-density requirements.

No Additional Rack Footprint

Integrates with the rear of the rack without consuming valuable additional white space.

Flexible Installation

Connection options support deployment in facilities with or without raised floors.

Monitoring and Control Options

An optional monitoring and display package can include door switches, temperature sensors and leak detection.

Long-Term Operation

A low-maintenance design with fewer moving components supports operational continuity.

Related Solutions

Liebert DCD delivers greater value when considered as part of an integrated high-density cooling architecture that includes racks, cooling distribution units, power distribution and monitoring. When combined with CDU-based liquid distribution systems, it can support more controlled water-temperature management and broader system integration.