Liebert ITA2 UPS

10–40 kVA | Three-Phase | Rack/Tower

Compact and reliable double-conversion power protection for computer rooms, storage systems and network equipment.

Up to 96.6% Double-Conversion Efficiency | Up to 99% ECO Efficiency |
Unity Output PF | 0.99 Input PF

Compact UPS | IT Rooms | Network and Storage

Compact Three-Phase UPS for Critical IT Loads

Liebert ITA2 combines online double-conversion technology with a unity output power factor to support power quality and continuity for critical IT loads. Its compact rack/tower form factor enables practical installation in space-constrained environments.

Flexible installation, grid and generator compatibility, and high-capacity charging support configurations tailored to different operating requirements. The 10–20 kVA models support three-phase or single-phase output, while the 30–40 kVA models provide three-phase output.

  • Unity output power factor
  • Compact rack/tower installation
  • Up to 99% efficiency in ECO mode

Key Features of Liebert ITA2

Unity Output Power Factor

Enables effective use of rated capacity for critical IT loads.

Double-Conversion and ECO Efficiency

Delivers up to 96.6% double-conversion and 99% ECO mode efficiency.

Compact Rack/Tower Design

Supports practical installation in IT rooms and space-constrained environments.

Fast Recharge and Scalable Runtime

High-capacity charging and flexible batteries enable faster recharge and scalable runtime.

Ideal Applications

Power Protection for Computer Rooms and Distributed IT

Liebert ITA2 helps stabilize power quality and reduce interruption risks for critical IT loads, including storage and network equipment. Its compact architecture and operational flexibility make it suitable for projects where continuity, space efficiency and ease of deployment are priorities.

Recommended Applications

  • Data centers, colocation and hosting facilities
  • Banking, financial services and insurance
  • Educational institutions
  • Government facilities
  • Retail and warehouse locations

Why Choose Liebert ITA2?

A compact UPS platform focused on installation flexibility, high power factor and operating efficiency.

Installation Flexibility

The rack/tower form factor and flexible output options support different deployment requirements.

High Power Factor

Unity output power factor and a 0.99 input power factor support effective capacity use and grid compatibility.

Operating Efficiency

Double-conversion and ECO operating modes help reduce energy consumption and operating costs.

Configuration and Options

Define the Right Runtime for Your Application

Liebert ITA2 can be configured with scalable battery runtime according to project requirements. Runtime targets, available space and maintenance requirements are evaluated together to determine the appropriate battery configuration.

  • Scalable runtime configuration
  • High-capacity charging for faster recovery
  • Compatible external battery modules

Plan Maintenance for the Compact Architecture

Bypass should be included in the system design to keep critical loads online during planned maintenance. An optional maintenance bypass cabinet can be configured for Liebert ITA2 service requirements.

  • Optional maintenance bypass cabinet
  • Simplified operation to reduce human error
  • Risk mitigation during maintenance windows

Scale Capacity Through Flexible Deployment

Parallel system configurations can support capacity expansion or redundancy targets, subject to model and application suitability. Capacity and redundancy requirements are evaluated together based on the project architecture.

  • Capacity scaling through parallel systems
  • Configuration based on capacity and redundancy targets
  • Architecture aligned with site conditions

Monitoring and Integration

Liebert ITA2 supports local and remote monitoring for greater operational visibility. Optional communication cards and SNMP-based monitoring enable integration with IT and building management platforms.

  • Local and remote monitoring
  • Vertiv IntelliSlot Unity communications card
  • SNMP, Modbus or relay communication

Technical Specifications

Power Range

10–40 kVA

Topology

Online double conversion

Efficiency

Up to 96.6% in double-conversion mode, depending on model; up to 99% in ECO mode

Output Power Factor

Unity, PF 1.0

Input Power Factor

0.99

Installation

Rack or tower

Output Configuration

10–20 kVA: three-phase or single-phase output; 30–40 kVA: three-phase output

Battery System

High-capacity charging with scalable runtime configurations

Strengthen Your Critical Power Infrastructure


Share your load profile, runtime targets and installation requirements so we can define the right Liebert ITA2 configuration.