Compact Three-Phase UPS for Critical IT Loads
Liebert ITA2 combines online double-conversion technology with a unity output power factor to support power quality and continuity for critical IT loads. Its compact rack/tower form factor enables practical installation in space-constrained environments.
Flexible installation, grid and generator compatibility, and high-capacity charging support configurations tailored to different operating requirements. The 10–20 kVA models support three-phase or single-phase output, while the 30–40 kVA models provide three-phase output.
Key Features of Liebert ITA2
Unity Output Power Factor
Enables effective use of rated capacity for critical IT loads.
Double-Conversion and ECO Efficiency
Delivers up to 96.6% double-conversion and 99% ECO mode efficiency.
Compact Rack/Tower Design
Supports practical installation in IT rooms and space-constrained environments.
Fast Recharge and Scalable Runtime
High-capacity charging and flexible batteries enable faster recharge and scalable runtime.
Ideal Applications
Power Protection for Computer Rooms and Distributed IT
Liebert ITA2 helps stabilize power quality and reduce interruption risks for critical IT loads, including storage and network equipment. Its compact architecture and operational flexibility make it suitable for projects where continuity, space efficiency and ease of deployment are priorities.
Recommended Applications
Why Choose Liebert ITA2?
A compact UPS platform focused on installation flexibility, high power factor and operating efficiency.
Installation Flexibility
The rack/tower form factor and flexible output options support different deployment requirements.
High Power Factor
Unity output power factor and a 0.99 input power factor support effective capacity use and grid compatibility.
Operating Efficiency
Double-conversion and ECO operating modes help reduce energy consumption and operating costs.
Configuration and Options
Define the Right Runtime for Your Application
Liebert ITA2 can be configured with scalable battery runtime according to project requirements. Runtime targets, available space and maintenance requirements are evaluated together to determine the appropriate battery configuration.
Plan Maintenance for the Compact Architecture
Bypass should be included in the system design to keep critical loads online during planned maintenance. An optional maintenance bypass cabinet can be configured for Liebert ITA2 service requirements.
Scale Capacity Through Flexible Deployment
Parallel system configurations can support capacity expansion or redundancy targets, subject to model and application suitability. Capacity and redundancy requirements are evaluated together based on the project architecture.
Monitoring and Integration
Liebert ITA2 supports local and remote monitoring for greater operational visibility. Optional communication cards and SNMP-based monitoring enable integration with IT and building management platforms.
Technical Specifications
Power Range
10–40 kVA
Topology
Online double conversion
Efficiency
Up to 96.6% in double-conversion mode, depending on model; up to 99% in ECO mode
Output Power Factor
Unity, PF 1.0
Input Power Factor
0.99
Installation
Rack or tower
Output Configuration
10–20 kVA: three-phase or single-phase output; 30–40 kVA: three-phase output
Battery System
High-capacity charging with scalable runtime configurations
Related Solutions
Strengthen Your Critical Power Infrastructure
Share your load profile, runtime targets and installation requirements so we can define the right Liebert ITA2 configuration.