Precision Cooling Systems

Liebert HPM
4 – 30 kW

A flexible and compact precision cooling solution for telecom facilities, server rooms and control centers

Maximum Flexibility, Compact Design

Liebert® HPM is a versatile precision cooling solution designed for technology environments such as telecom facilities, control rooms, server rooms and data centers.

Its compact architecture combines reliable performance with flexible installation options. Direct expansion (DX) and chilled-water (CW) versions support different cooling requirements, while multiple airflow configurations simplify integration into a wide range of technical spaces.

Easy Maintenance and Access

A user-friendly interface and full front access to mechanical components help simplify servicing and reduce maintenance time.

Energy-Efficient Operation

Optimized internal airflow and next-generation EC fans help reduce operating costs while supporting ErP 2015 compliance.

Flexible Configuration

DX and chilled-water versions are available with downflow, upflow and displacement airflow options for different room layouts.

Intelligent and Reliable Control

Vertiv™ iCOM™ control, Teamwork functionality and BMS integration coordinate system operation and improve reliability.

Ideal Applications

Compact Technical Rooms and IT Environments

Liebert HPM is designed for low- and medium-capacity cooling requirements from 4 to 30 kW. Its compact and flexible architecture is particularly suitable for telecom facilities, control rooms and smaller server environments.

Recommended Applications

  • Telecommunications
  • Banking, financial services and insurance
  • Data centers, colocation and hosting facilities
  • Manufacturing facilities
  • Broadcasting and entertainment
  • Retail and wholesale environments
  • Transportation facilities

Liebert HPM: Technical Specifications and Configurations

Direct Expansion (DX) Version

High-efficiency DX configurations using R410A refrigerant across a capacity range of 6.6–25.0 kW.

  • Capacity range: 6.6–25.0 kW
  • Net cooling capacity: 5.1–21.5 kW
  • Refrigerant: R410A
  • Fan technology: Next-generation EC fans

Chilled-Water (CW) Version

Flexible chilled-water configurations compatible with different water-temperature regimes, including 7/12°C and 10/15°C.

  • Capacity range: 4.1–28.8 kW
  • Control system: Vertiv™ iCOM™ control
  • Airflow options: Downflow, upflow and displacement

Critical Systems, Engineered for What’s Next